| bio | website | |
|---|---|---|
| location | ||
| age | 19 | |
| visits | member for | 1 year, 6 months |
| seen | 4 hours ago | |
| stats | profile views | 22 |
Finishing college with my internship this semester and going to university in software engineering.
I have some experience in .NET and Java, along with some Lua and COBOL.
|
May 11 |
comment |
Lua - Removing words that are not in a list Instead of concatenating the string in the loop, you could just send in a space as a second parameter: table.concat(retstring, " ") |
|
Apr 21 |
accepted | Referencing WiX extension in same solution as wixproj |
|
Apr 21 |
answered | Referencing WiX extension in same solution as wixproj |
|
Apr 16 |
asked | Referencing WiX extension in same solution as wixproj |
|
Apr 12 |
comment |
Detect if last character is not multibyte in Lua @m.buettner Well, I never... Learn something new everyday. |
|
Apr 12 |
comment |
Detect if last character is not multibyte in Lua @m.buettner I just tested it, actually. Not sure if they changed the behaviour in 5.2, but it does work in 5.1. Try it out. |
|
Apr 12 |
comment |
Detect if last character is not multibyte in Luastring.sub(str, stringLength,stringLength) does indeed return the last character in str. Just be sure not to name your variable string, as that conflicts with the string table. Also, could you elaborate what you mean by multibyte character? |
|
Apr 12 |
revised |
lua code deobfuscation added 137 characters in body |
|
Apr 12 |
answered | lua code deobfuscation |
|
Apr 10 |
comment |
Getting the file version of a native exe in MSBuild Would using a preprocessor extension to grab the file version be out of the question? |
|
Apr 8 |
revised |
Find XML node in C# ignore the rest Added an example |
|
Apr 8 |
answered | Find XML node in C# ignore the rest |
|
Mar 28 |
comment |
Add External DLL to WIX project @PLAudet You could use a preprocessor pragma that calls heat, reads the output and writes it to your wxs file. |
|
Mar 27 |
comment |
Avoid to add components manually @Kowsika Try "%wix%\bin\heat" -?. Don't forget the quotes. |
|
Mar 25 |
comment |
how to find the status of executed MSI from the command prompt As Ciprian said, you can enable logging using msiexec /i "C:\...\setup.msi" /l*xv log.txt. Then use net helpmsg 0000 to know what each error message means. For example 1603 is fatal error during installation. |
|
Mar 24 |
awarded | Fanatic |
|
Mar 21 |
accepted | Path unavailable error during setup |
|
Mar 20 |
answered | Path unavailable error during setup |
|
Mar 20 |
revised |
Path unavailable error during setup added 90 characters in body |
|
Mar 19 |
answered | Separate Publish Event from Control |